Published on Australian Maritime Safety Authority (https://www.amsa.gov.au)
AMSA audits recently accredited marine surveyors to ensure the correct procedures and protocols set out in the National Law - Marine Surveyors Accreditation Guidance Manual (SAGM) and the Marine Safety (Domestic Commercial Vessel) National Law Regulation 2013 (the regulations) are followed. These audits identify issues that may arise in the early stages of a surveyor's activity.
Observations and non-conformances will be provided in writing to the surveyor for action.
Audits also occur because of complaints received or non-conformances detected during our assessment of survey applications. The three cases below are examples where major non-conformances were identified.
A certificate of survey application for a new build 2B vessel was refused when several major non-conformances were identified. The non-conformances included, but were not limited to:
The surveyors involved were counselled for contravention of conditions of accreditation. The vessel has since undergone modifications and a new application for a certificate of survey has been submitted.
An AMSA inspection identified a 3B vessel had undergone a major refit. The vessel had permanent ballast removed and major hull and structure replacements were carried out. Fish linings, tanks and freezers were also removed, and the vessel’s stability needed to be reassessed. The accredited surveyor made an error in assuming these works could be undertaken as a renewal survey instead of an initial survey to the transitional vessel standards.
The vessel’s certificate of survey was suspended without a show cause notice as there was clear intention to operate the vessel without a revised stability assessment. The vessel remains unable to operate without contravening S11(1) (h) of Marine Order 503, pending an initial survey.
The accredited surveyor was issued a notice of decision letter refusing a further time period to renew their accreditation under the National Law. The surveyor had failed to apply to renew their accreditation within the timeframes set out by the regulations. The surveyor is no longer accredited after they chose not to submit an initial application and undergo an interview.
AMSA conducted inspections on two 2C sister vessels after receiving a complaint. Major non-conformances were identified following a physical practical stability test of the vessels.
The surveyor had initial survey categories revoked following an audit and show cause process. The certificates of survey were revoked for both vessels, and the owner has settled a claim against the builder and surveyor involved.
AMSA will stop receiving emailed survey reports from 1/12/2021. This means accredited marine surveyors and Recognised Organisation surveyors need to submit their reports and recommendations directly into MARS from this date. We are making this change so that our stakeholders (your clients) receive their certification as soon as possible. This change will increase the efficiency of certification processes.
To prepare for this change surveyors will need to ensure your MARS login details (username and password) are current. You will need to download the free ‘VIP Access’ app to your desktop or mobile device. Chapter 3 of the MARS user guide contains the steps to get set up and log in. The user guide is available on the AMSA website here. If you need help setting up, you can email mars.support@amsa.gov.au for assistance.
You should review the rest of the user guide to ensure you are familiar with uploading survey reports directly into MARS. If you currently submit your reports via email, you now have almost three months to transition to lodging reports directly into MARS.
Please note the MARS user guide and associated web pages will be updated to reflect the change in process.
Yes, AMSA provides the option to set up company access so an administrative representative can claim and enter surveys on behalf of a surveyor. Send an email to DCVSurvey@amsa.gov.au if you would like to set up company access.
There are some exceptions to the rule. AMSA will accept emailed submissions when:
If you conduct an additional survey that doesn’t align with a vessels survey cycle, for example a repair survey, you can email DCVApplications@amsa.gov.au and ask for a code to be generated. This process also applies for surveys conducted on vessels that aren’t required to hold a certificate of survey, for example vessels operating under EX02 Division 5.
There is no change to the process already in place. If an accredited surveyor conducts a survey on a vessel greater than 35 metres they must email DCVSurvey@amsa.gov.au and provide:
Any questions about this update can be directed to DCVSurvey@amsa.gov.au
AMSA continues to receive recommendations from surveyors where non-compliant structural fire protection has been fitted to vessels. These non-conformances have significant impacts for builders, surveyors and vessel owners. AMSA recently refused an application for a certificate of survey for a new build vessel fitted with non-compliant structural fire protection, among other non-conformances.
We wrote about passive fire protection measures in the April 2020 edition of Survey Matters. The information is reproduced below to reiterate the importance of compliant structural fire protection.
Structural fire protection is installed on the vessel structure to contain or slow the spread of fire. It includes the installation of fire-resistant bulkheads, deck heads, decks and doors.
The primary aims of structural fire protection are:
Passive structural fire protection works in four main ways:
Structural fire protection guards essential components and compartments against fire and thermal heat, to maintain structural integrity.
Compartmentation includes fire-rated divisions or compartments, bulkheads, deck heads, and smoke barriers. It seeks to contain the spread of fire, thermal mass and smoke. Fire can be contained within the machinery space, for example, if the bulkheads and decks are sufficiently protected.
Fire doors and fire-resistant penetrations installed in openings aim to maintain fire-resistance. They work together to form an effective smoke and fire barrier.
These materials generally withstand temperatures exceeding 1200°C for extended time periods. This limits fire spread.
Note: It’s common to see a fire-rated division penetrated during modifications. Workers may leave hidden holes in the division as they perform maintenance and upgrades. Surveyors need to pay attention to fire-rated divisions and ensure they are maintained to the original approved specification. This includes paying close attention to cable and pipe penetrations.
The type and thickness of insulation depends on the material it is protecting. For example; steel begins to lose its design margin of safety at temperatures of around 550°C. For aluminium the temperature is much lower at around 150°C. At 275°C aluminium will lose around 50% of its yield strength. Composites soften as temperatures rise, resulting in reduced structural properties for a laminate. The glass transition temperature of the resin affects the amount of insulation required for a composite. Performance of cores & fibres across a range of temperatures also impacts the amount required.
The April 2020 edition of Survey Matters contains the basic principles and examples of data sheets and certificates of compliance for Aluminium - A30, Steel - A30, and Composite - A60 structural fire protection.
Installing protection under approved design and OEM guidelines is the only way to achieve the aims mentioned above. This includes:
Pink batts are not acceptable. They are combustible above 350°C and are designed for comfort insulation and acoustic use only.
Intumescent paints and similar solutions do not meet the performance requirements for use. They are not approved for use as structural fire protection solutions.
A solution approved for use on steel, is not necessarily suitable for use on aluminium or fibreglass. Even if it is certified for a higher time rating than required.
A solution approved for use in a land-based building is not approved for use on a vessel. The performance criteria are significantly different between vessels and buildings. The environment, firefighter response time and distance to safety or rescue if a fire breaks out differ.
AMSA has noticed there is some confusion about what items must be surveyed as part of a periodic out of water survey. The confusion stems from the out of water survey items section at the bottom of Table 9 in chapter 4 of SAGM Part 2.
The out of water survey items section is not an exhaustive list of items that must be surveyed as part of a periodic out of water survey. The whole of table 9 must be considered when conducting a periodic out of water survey and any item with a tick next to it must be surveyed.
When you conduct a survey for an OWAT code, ensure all applicable items in Table 9 are examined, verified, tested or trialled, and documented on your reports.
AMSA frequently receives enquiries from vessel owners and operators regarding the navigation light requirements for domestic commercial vessels. During audits we have also noticed that navigational light arrangement plans are commonly omitted, or these details aren’t reflected in the general arrangement plan as part of the initial survey documentation.
For vessels which must comply with Pt. C of COLREGs, AMSA expects that a navigation light arrangement plan, approved by an AMS, is available on board. This plan may contain details regarding the different types of navigation light, minimum range of visibility, horizontal and vertical positioning and spacing of the lights etc.
Alternatively, for smaller vessels, these details can be provided on the general arrangement Plan.
A profile view and table of navigation lights on a ship over 50m is shown below for illustration purposes only (not to scale).
Item number | Light | Type | SI number | Range | Visibility | Colour |
---|---|---|---|---|---|---|
1 | Fore Masthead Light | -- | -- | 225° | 6nm | White |
2 | Aft Masthead Light | -- | -- | 225° | 6nm | White |
3 | ------- | -- | -- | -- | -- | -- |
LED navigation lights can be installed, subject to several conditions listed in IMO resolution MSC.253 (83).
However, AMSA reminds all owners, operators and accredited surveyors that the luminous intensity of LEDs gradually decreases while the electricity consumption remains unchanged. The rate of decrease of luminous intensity depends on the output and temperature of the LEDs.
Marine Order 30 requires navigation lights, navigation light controllers and associated equipment, installed on DCVs after 30 November 2009 to conform to performance standards at least equal to those mentioned in the Annex to IMO Resolution MSC.253(83).
To prevent shortage of luminous intensity of LEDs, the following additional requirements have been specified in IMO Resolution MSC.253 (83):
or
Accredited surveyors are encouraged to check the following documentation/marking checks in addition to the routine safety and operation checks;
If expiry dates aren’t specified by the manufacturer, check for alarm functions on the bridge for reduction in luminous intensity of LED Navigation Lights.
The Surveyor Manual Part 2 Table 2 requires that a lines plan (or electronic 3D hull file) is provided when comprehensive stability criteria is used. This is expanded in NSCV C6C, clause A8.8.4 as part of the information supporting the inclining experiment.
This may elicit concern, as it is a valuable piece of intellectual property. AMSA appreciate that a lines plan represents sensitive proprietary hull design information often built up over many years. It can also represent a significant investment of time to model an existing vessel, providing a competitive advantage.
We understand and appreciate these concerns. AMSA has a comprehensive privacy policy on our website.
The rationale behind the requirement for lines plan data (either in the form of a drawing or a 3D hull model) is to permit audit in accordance with section 45 of the regulations.
Another reason for requiring a lines plan is to aid investigation in the event of an incident linked to the vessel stability. Should stability need to be assessed the provision of hull data allows for this to be undertaken.
Hence, when comprehensive stability is used on a vessel, either a lines plan containing the data listed in Table 2 of SAGM Part 2, or an electronic hull file, such as a Maxsurf hull file or *.iges is required in support of a recommendation for stability approval.
AMSA has recently seen an increase in the use and application of autonomous vessels in Australia. AMSA has produced guidance material to assist operators of these vessels to comply with the national system. The guidance notice is now available on the AMSA website and helps improve our regulation of emerging technology in Australia.
Guidance Notice – Small unmanned autonomous vessels
As a part of global measures to reduce harmful nitrogen oxide (NOx) emissions, marine diesel engines with an output above 130kW must now meet NOx emission requirements.
Globally, the shipping industry is reducing NOx emissions by requiring marine diesel engines with a power output of greater than 130kW to comply with NOx emission limits. To confirm an engine is compliant, an Engine international air pollution prevention (EIAPP) certificate and a technical file must be carried on board for each engine.
AMSA has introduced measures that will assist DCV owners and operators comply with the NOx emission requirements. Under Exemption 44, DCV owners and operators can hold specified alternative evidence that demonstrates engines are likely to meet the NOx emission limits.
Read more information about the requirements
The National Compliance Plan 2021-22 provides practical guidance and a clear view of what AMSA will be looking for over the coming year to make it easier to comply with the national law.
Focus area 3 in the plan specifically addresses domestic commercial vessels. The importance of safety management systems, incident reporting, fatigue management, and compliance with the marine surveyors’ accreditation guidance manual are priority areas for AMSA’s compliance activities over the coming year.
Focus areas 4 and 5 are also targeted to domestic commercial vessels to increase beacon registration and prevent pollution from ships.
Please familiarise yourself with the priority areas and share this information with your clients as the opportunity arises.
Is there a topic you’d like to see covered in a future edition of Survey Matters? Send an email to DCVSurvey@amsa.gov.au with any suggestions or feedback.